PURPOSE

To evaluate the effectiveness, predictability, and safety of laser in situ keratomileusis (LASIK) for correcting residual myopia after cataract surgery with intraocular lens implantation.

METHODS

Twenty-two eyes of 22 patients underwent LASIK for the correction of residual myopia after cataract surgery. LASIK was carried out using the Chiron Automated Corneal Shaper and the NIDEK EC-5000 excimer laser. In all eyes, the follow-up was 12 months.

RESULTS

Before LASIK, 1 eye (4.5%) had an uncorrected visual acuity of 0.5 or better; 12 months after LASIK, 10 eyes (45.4%) achieved this level of visual acuity and 0 eyes achieved 1.00 or better. Before LASIK, mean refraction was -2.90 ± 1.80 D; 12 months after LASIK it decreased significantly to 0.40 ± 0.60 D (P < .01). In 18 eyes (81.8%) at 12 months after LASIK, spherical equivalent refraction was within ±1.00 D of emmetropia; 11 eyes (50%) were within 0.50 D. No vision-threatening complications occurred.

CONCLUSION

LASIK with the Automated Corneal Shaper and Nidek EC-5000 excimer laser was an effective, predictable, stable, and safe procedure for correcting residual myopia after cataract surgery. No intraocular lens or cataract incision related complications occurred when LASIK was performed at least 3 months after phacoemulsification. [J Refract Surg 2001;17:12-16]

AUTHORS

From the Refractive Surgery and Cornea Department, Alicante Institute of Ophthalmology, Miguel Hernández University School of Medicine, Alicante, Spain.

None of the authors has a propietary interest in any material described herein.

Correspondence: Maria J. Ayala, MD, Refractive Surgery and Cornea Department, Alicante Institute of Ophthalmology, Avd Denia 111, 03015-Alicante, Spain. Tel: 34.96.5919378; Fax: 34.96.5919420; E-mail: oftalio@ibm.net

Received: February 3, 1999

Accepted: September 18, 2000

* Read the full text of this and other articles (ISRS members only)

* About SLACK Inc.
* Go to Eye Care Internet Resources.
* Go to Journal of Refractive Surgery.
* Read abstracts (open to all visitors).
* Read full articles (ISRS members, only).
* Try out a free issue.
* Take out a subscription.
* Visit the ISRS Web site.

* Copyright 2001, SLACK Incorporated. Revised 22 January 2001.
* Send a letter to the editor.
* Comment to Webmaster, SLACK Inc.